Conventional colonoscopy represents the gold standard for the detection of colorectal pathologies. However, due to its invasiveness and procedure-related discomfort, patient acceptance is somtimes poor. In the last few years, the use of MR Colonography has been shown to be an appropriate diagnostic tool for the detection of colorectal pathologies. Dark-lumen MR Colonography has been introduced. This technique is based on the acquisition of a T1-weighted sequence following the administration of a water-enema and the intravenous administration of paramagnetic contrast. This review article describes the underlying technique of dark-lumen MR Colonography, the process of data acquisition, image interpretation, as well as application and accuracy. Additionally, the benefits of this approach compared to conventional colonoscopy, new techniques to improve patient acceptance and diagnostic accuracy will be reviewed. Keywords: Conventional colonoscopy, virtual
Ajaj, Prof. Dr. W. (2012). Clinical use of MRI: Virtual Dark-Lumen MR Colonography: Technique, Application and Accuracy. An-Najah University Journal for Research - B (Humanities), 2(1), 3–21. https://doi.org/10.35552/0247-002-001-002
[1]Prof. Dr. W. Ajaj, “Clinical use of MRI: Virtual Dark-Lumen MR Colonography: Technique, Application and Accuracy,” An-Najah University Journal for Research - B (Humanities), vol. 2, no. 1, pp. 3–21, Jan. 2012, doi: 10.35552/0247-002-001-002.
Ajaj, Prof. Dr. Waleed. “Clinical Use of MRI: Virtual Dark-Lumen MR Colonography: Technique, Application and Accuracy.” An-Najah University Journal for Research - B (Humanities), vol. 2, no. 1, Jan. 2012, pp. 3–21. Crossref, https://doi.org/10.35552/0247-002-001-002.
1.Ajaj ProfDrW. Clinical use of MRI: Virtual Dark-Lumen MR Colonography: Technique, Application and Accuracy. An-Najah University Journal for Research - B (Humanities) [Internet]. 2012 Jan;2(1):3–21. Available from: http://dx.doi.org/10.35552/0247-002-001-002
Ajaj, Prof.Dr. Waleed. “Clinical Use of MRI: Virtual Dark-Lumen MR Colonography: Technique, Application and Accuracy.” An-Najah University Journal for Research - B (Humanities) 2, no. 1 (January 2012): 3–21. https://doi.org/10.35552/0247-002-001-002.
Clinical use of MRI: Virtual Dark-Lumen MR Colonography: Technique, Application and Accuracy
المؤلفون:
معلومات المقال
2011-12-21
2012-06-27
2012-06-27
3 - 21
الكلمات الإفتتاحية
الملخص
Conventional colonoscopy represents the gold standard for the detection of colorectal pathologies. However, due to its invasiveness and procedure-related discomfort, patient acceptance is somtimes poor. In the last few years, the use of MR Colonography has been shown to be an appropriate diagnostic tool for the detection of colorectal pathologies. Dark-lumen MR Colonography has been introduced. This technique is based on the acquisition of a T1-weighted sequence following the administration of a water-enema and the intravenous administration of paramagnetic contrast. This review article describes the underlying technique of dark-lumen MR Colonography, the process of data acquisition, image interpretation, as well as application and accuracy. Additionally, the benefits of this approach compared to conventional colonoscopy, new techniques to improve patient acceptance and diagnostic accuracy will be reviewed. Keywords: Conventional colonoscopy, virtual
Ajaj, Prof. Dr. W. (2012). Clinical use of MRI: Virtual Dark-Lumen MR Colonography: Technique, Application and Accuracy. An-Najah University Journal for Research - B (Humanities), 2(1), 3–21. https://doi.org/10.35552/0247-002-001-002
[1]Prof. Dr. W. Ajaj, “Clinical use of MRI: Virtual Dark-Lumen MR Colonography: Technique, Application and Accuracy,” An-Najah University Journal for Research - B (Humanities), vol. 2, no. 1, pp. 3–21, Jan. 2012, doi: 10.35552/0247-002-001-002.
Ajaj, Prof. Dr. Waleed. “Clinical Use of MRI: Virtual Dark-Lumen MR Colonography: Technique, Application and Accuracy.” An-Najah University Journal for Research - B (Humanities), vol. 2, no. 1, Jan. 2012, pp. 3–21. Crossref, https://doi.org/10.35552/0247-002-001-002.
1.Ajaj ProfDrW. Clinical use of MRI: Virtual Dark-Lumen MR Colonography: Technique, Application and Accuracy. An-Najah University Journal for Research - B (Humanities) [Internet]. 2012 Jan;2(1):3–21. Available from: http://dx.doi.org/10.35552/0247-002-001-002
Ajaj, Prof.Dr. Waleed. “Clinical Use of MRI: Virtual Dark-Lumen MR Colonography: Technique, Application and Accuracy.” An-Najah University Journal for Research - B (Humanities) 2, no. 1 (January 2012): 3–21. https://doi.org/10.35552/0247-002-001-002.
Why should you
Publish With Us?
An-Najah National University
Nablus, Palestine
Nablus, Palestine
- P.O. Box
- 7, 707
- Fax
- (970)(9)2345982
- Tel.
- (970)(9)2345560
- (970)(9)2345113/5/6/7-Ext. 2628
- [email protected]
- EIC
- Prof. Waleed Sweileh